CT8025 Applications
- Measure engine RPM, ignition
dwell angle, and temperature of exhaust manifold, cooling system,
air conditioning, heating system, catalytic
converter, etc.
- Measure output in sensors
like Oxygen (O2), Coolant Temperature, Throttle Position (TPS),
Manifold Air, Pressure (MAP),
Manifold Air Flow (MAF),
etc.
- Check grounds, Voltage
drops and continuity across Connectors, Wires, Cables, Relays Contacts,
Lamps, Switches, etc.
- Check components like
Alternator, Diodes, Relays Coils, Condensers, Ignition Coils, Spark
Plug Wires, Magnetic
Pick-ups, Motors,
Switches, Fuses,
etc.
- An essential tool for
all around troubleshooting of electrical and electronic circuit
and systems.
|
Technical Specifications :
General Specifications:
- Display:
- 3½ Digit
LCD (Max reading 1999)
- 1/2”(12.5 mm)
Digits
- High Voltage warning
indicator
- Automatic( - ) negative
polarity indicator
- Automatic Zeroing
- Automatic over-range
indication
- Low battery indicator
- Power source: Standard
9 Volt alkaline battery type NEDA 1604 IEC 6F 22
- Test probes: One red and one black, 1000V/10A rated (IEC1010/EN61010 CAT
II), 35½" long, K-type temperature probe.
- Physical
dimensions: 5.51” (H) x 2.75” (W) x 1.41” (D)
- 140 mm (H) x 70 mm (W) x 36 mm (D)
- Weight: Approximately 12.34 Oz ( 350 g) Including battery
- Electrical
Specifications:
- DC Voltage: ±0.25% ± 2
dgts., 1MOhm input impedance, 600 V ac/dc Overload protection
- AC Voltage: ±1.5% ± 5 dgts., 450KOhm
input impedance, 40 to 200 Hz, 600 V ac/dc Overload protection
- Resistance: ±1.0% ± 3
dgts., 250 V ac/dc Overload protection
- DC Current: ± 1.0
% ± 3 dgts., Internal 10A/ 250V fuse
protection
- Diode test: 2.4 ± 0.6 mA test current,
3.2 V max. test voltage
- Continuity Test: Audible indicator
(Buzzer) with circuit resistance is below 100 Ohm
- Temperature: -40º to 400°C (±0.7 + 3 dgts.), 400°C
to 1000°C (±1.5 + 10 dgts.)
|